Home > Products
 
 
  Name/Model:   Closed-loop Hall current sensor LA-50T, 100T
  Rated input Parameter:   DC, AC or pulsed 50A, 100A current / PCB / Bus bar
  Download:   Download the manual

SENSOR MODULE  LA-50T, 100T

The SENSOR Module LA-50T, 100T is a closed loop Hall current sensor to measure 50A, 100A DC, AC

or pulsed currents with a galvanic isolation between the primary and secondary circuits.

 

Closed-loop Hall Current Sensor:

Type

Nominal current

Output current

Accuracy

Supply voltage

Aperture

INA

IMmA

X%

VcV

mm

LA-50T

50

50

±0.5%

±12...15

Bus bar

LA-100T

100

50

±0.5%

±12...15

Bus bar

 

Specifications: 

Principle

Closed loop Hall effect principle

Input current

50…100ADCACPulsed current

Output current

50mA

Turns ratio

1:100050A);1:2000100A

Frequency

DC~100KHz

Accuracy

±0.5%

Response time

<1μS

Linearity

<0.1%

Supply voltage

±12...15V±5%

Consumption

10mA+IMOutput current

Isolation voltage

Between primary and secondary circuit: 2KV or 3KV RMS/50Hz/1min.

Operating temp.

-25…+85

Mounting on

PCB

Applications

Power supplies, welding machines, converters, industry auto-control, motor drives,

For industry

electronic power system, railways, rectifiers systems etc.