Name/Model: |
Closed-loop Hall current sensor LA-50T, 100T |
Rated input Parameter: |
DC, AC or pulsed 50A, 100A current / PCB / Bus bar |
Download: |
Download the manual |
|
SENSOR MODULE LA-50T, 100T |
The SENSOR Module LA-50T, 100T is a closed loop Hall current sensor to measure 50A, 100A DC, AC |
or pulsed currents with a galvanic isolation between the primary and secondary circuits. |
|
Closed-loop Hall Current Sensor: |
Type |
Nominal current |
Output current |
Accuracy |
Supply voltage |
Aperture |
IN(A) |
IM(mA) |
X(%) |
Vc(V) |
mm |
LA-50T |
50 |
50 |
±0.5% |
±12...15 |
Bus bar |
LA-100T |
100 |
50 |
±0.5% |
±12...15 |
Bus bar |
|
Specifications: |
Principle |
Closed loop Hall effect principle |
Input current |
50…100A(DC、AC、Pulsed current) |
Output current |
50mA |
Turns ratio |
1:1000(50A);1:2000(100A) |
Frequency |
DC~100KHz |
Accuracy |
±0.5% |
Response time |
<1μS |
Linearity |
<0.1% |
Supply voltage |
±12...15V(±5%) |
Consumption |
10mA+IM(Output current) |
Isolation voltage |
Between primary and secondary circuit: 2KV or 3KV RMS/50Hz/1min. |
Operating temp. |
-25…+85℃ |
Mounting on |
PCB |
Applications |
Power supplies, welding machines, converters, industry auto-control, motor drives, |
For industry |
electronic power system, railways, rectifiers systems etc. |
>>Back |
|
|
|
|