Name/Model: |
Closed-loop Hall current sensor CHB-6KA~25KA |
Rated input Parameter: |
DC, AC or pulsed 6KA~25KA current / Split core |
|
SENSOR MODULE CHB-6KA~25KA |
The SENSOR Module CHB-6KA~25KA is a closed loop Hall current sensor to measure 6KA~25KA DC, AC |
or pulsed currents with a galvanic isolation between the primary and secondary circuits. |
|
Closed-loop Hall Current Sensor: |
Type |
Nominal current |
Output current |
Accuracy |
Supply voltage |
Aperture |
IN(A) |
IM(mA) |
X(%) |
Vc(V) |
mm |
CHB-6KA |
6000 |
1200 |
±0.4% |
±24 |
250X250 |
CHB-10KA |
10000 |
2000 |
±0.4% |
±24 |
250X250 |
CHB-15KA |
15000 |
3000 |
±0.4% |
±24 |
250X250 |
CHB-20KA |
20000 |
4000 |
±0.4% |
±36 |
250X250 |
CHB-25KA |
25000 |
5000 |
±0.4% |
±40 |
250X250 |
|
Specifications: |
Principle |
Closed loop Hall effect principle |
Input current |
6,000A~25,000A(DC、AC、Pulsed current) |
Output current |
1,200mA~5,000mA |
Turns ratio |
1:5000 |
Frequency |
DC~20KHz |
Accuracy |
±0.4% |
Response time |
<1μS |
Linearity |
<0.1% |
Supply voltage |
±24~40V(±5%) |
Consumption |
90mA+IM(Output current) |
Isolation voltage |
Between primary and secondary circuit: 10KV RMS/50Hz/1min. |
Operating temp. |
-25…+70℃ |
Mounting on |
Fastening on panel |
Applications |
Power supplies, industry auto-control, electronic power, rectifiers systems etc. |
>>Back |
|
|
|
|