  Name/Model:   Closed-loop Hall voltage sensor CHV-100/100~500(A)
  Rated input Parameter:   DC, AC or pulsed 100V~500V voltage
  Download:   Download the manual

SENSOR MODULE  CHV-100/100~500(A)

The SENSOR Module CHV-100/100~500 is a closed loop Hall voltage sensor to measure 100V…500V DC, AC

or pulsed voltages with a galvanic isolation between the primary and secondary circuits.

 

Closed-loop Hall Voltage Sensor: Output 5V

Type

Nominal voltage

Output voltage

Accuracy

Supply voltage

Connection

VNV

VMV

X%

VcV

Input

CHV-100/100

100

5

±0.5%

±12~15

Terminals

CHV-100/300

300

CHV-100/500

500

 

Closed-loop Hall Voltage Sensor: Output 25mA

Type

Nominal voltage

Output current

Accuracy

Supply voltage

Connection

VNV

IMmA

X%

VcV

Input

CHV-100/100A

100

25

±0.5%

±12~15

Terminals

CHV-100/300A

300

CHV-100/500A

500

 

Specifications: 

Principle

Closed loop Hall effect principle

Input voltage

100…500V (DCACPulsed voltage

Output

5V/25mA

Frequency

DC~20KHz

Accuracy

±0.5%

Response time

40…200μS

Linearity

0.1%

Supply voltage

±12~15V±5%

Consumption

10mA+IMOutput current

Isolation voltage

Between primary and secondary circuit: 6KV RMS/50Hz/1min.

Operating temp.

-25…+70

Mounting on

Fastening on panel

Applications

Power supplies, welding machines, converters, industry auto-control, motor drives,

For industry

electronic power system, railways, rectifiers systems etc.

>>back