SENSOR MODULE CHV-20L |
The SENSOR Module CHV-20L is a closed loop Hall voltage sensor to measure 10V…300V(100mA) DC, AC |
or pulsed voltages with a galvanic isolation between the primary and secondary circuits. |
|
Closed-loop Hall Voltage Sensor: |
Type |
Nominal current |
Output voltage |
Accuracy |
Supply voltage |
Connection |
IN(mA) |
VM(V) |
X(%) |
Vc(V) |
Input |
CHV-20L |
100 |
5 |
±1.0% |
±12~15 |
PCB |
|
Specifications: |
Principle |
Closed loop Hall effect principle |
Input current |
100mA(10V…300V DC、AC、Pulsed voltage) |
Output voltage |
5V |
Turns ratio |
200:1000 |
Frequency |
DC~20KHz |
Accuracy |
±1.0% |
Response time |
40μS |
Linearity |
0.1% |
Supply voltage |
±12~15V(±5%) |
Consumption |
10mA+IM(Output current) |
Isolation voltage |
Between primary and secondary circuit: 2.5KV RMS/50Hz/1min. |
Operating temp. |
-25…+70℃ |
Mounting on |
PCB |
Applications |
Power supplies, welding machines, converters, industry auto-control, motor drives, |
For industry |
electronic power system, railways, rectifiers systems etc. |
>>back |