Home > Products
 
 
  Name/Model:   Closed-loop Hall voltage sensor CHV-20L
  Rated input Parameter:   DC, AC or pulsed 10V~300V (100mA) voltage / PCB
  Download:   Download the manual

SENSOR MODULE  CHV-20L

The SENSOR Module CHV-20L is a closed loop Hall voltage sensor to measure 10V…300V(100mA) DC, AC

or pulsed voltages with a galvanic isolation between the primary and secondary circuits.

 

Closed-loop Hall Voltage Sensor:

Type

Nominal current

Output voltage

Accuracy

Supply voltage

Connection

INmA

VMV

X%

VcV

Input

CHV-20L

100

5

±1.0%

±12~15

PCB

 

Specifications: 

Principle

Closed loop Hall effect principle

Input current

100mA10V…300V DCACPulsed voltage

Output voltage

5V

Turns ratio

200:1000

Frequency

DC~20KHz

Accuracy

±1.0%

Response time

40μS

Linearity

0.1%

Supply voltage

±12~15V±5%

Consumption

10mA+IMOutput current

Isolation voltage

Between primary and secondary circuit: 2.5KV RMS/50Hz/1min.

Operating temp.

-25…+70

Mounting on

PCB

Applications

Power supplies, welding machines, converters, industry auto-control, motor drives,

For industry

electronic power system, railways, rectifiers systems etc.

>>back